Western Indiantown Road Improvements - Add Auxiliary Lane(S)
Palm Beach County · est $1.8M
Bid dateFriday, May 8—
Palm Beach County · est $1.8M
Bid form · FDOT
104 advertised pay items from the FDOT bid form. Open a category to see its items — unit prices appear here once bids open.
| 0101-1 | MOBILIZATION (45456415201) | Lump sum |
| 0102-1 | MAINTENANCE OF TRAFFIC (45456415201) | Lump sum |
| 0102-14 | TRAFFIC CONTROL OFFICER | 36 HR |
| 0102-60 | WORK ZONE SIGN | 2,163 ED |
| 0102-71-13 | TEMPORARY BARRIER, F&I, LOW PROFILE, CONCRETE | 1,015 LF |
How to read this. Plan‑pull counts come straight from agency portals. Patterns and confidence scores are derived from comparable lettings (same county, same category, three‑year basis). Confidence is a calibration of past correctness on signals of this shape — not a guarantee of this bid’s outcome. We never round up. More on what Cassandri does →
| 0102-74-1 |
| CHANNELIZING DEVICE- TYPES I, II, DI, VP, DRUM, OR LCD |
| 4,436 ED |
| 0102-74-8 | CHANNELIZING DEVICE- PEDESTRIAN LCD (LONGITUDINAL CHANNELIZING DEVICE) | 2,254 FD |
| 0102-76 | ARROW BOARD / ADVANCE WARNING ARROW PANEL | 32 ED |
| 0102-99 | PORTABLE CHANGEABLE MESSAGE SIGN, TEMPORARY | 175 ED |
| 0102-104 | TEMPORARY SIGNALIZATION AND MAINTENANCE, INTERSECTION | 384 ED |
| 0102-107-1 | TEMPORARY TRAFFIC DETECTION AND MAINTENANCE, INTERSECTION | 384 ED |
| 0102-115 | TYPE III BARRICADE | 820 ED |
| 0104-10-3 | SEDIMENT BARRIER | 850 LF |
| 0107-1 | LITTER REMOVAL | 5.87 AC |
| 0107-2 | MOWING | 3.22 AC |
| 0110-1-1 | CLEARING & GRUBBING (45456415201) | Lump sum |
| 0110-4-10 | REMOVAL OF EXISTING CONCRETE | 1,047 SY |
| 0120-1 | REGULAR EXCAVATION | 1,101.1 CY |
| 0120-6 | EMBANKMENT | 0.1 CY |
| 0160-4 | TYPE B STABILIZATION | 1,176 SY |
| 0285-709 | OPTIONAL BASE, BASE GROUP 09 | 955 SY |
| 0327-70-6 | MILLING EXISTING ASPHALT PAVEMENT, 1 1/2" AVG DEPTH | 6,476 SY |
| 0334-1-13 | SUPERPAVE ASPHALTIC CONC, TRAFFIC C | 157.6 TN |
| 0337-7-83 | ASPHALT CONCRETE FRICTION COURSE,TRAFFIC C, FC-12.5, PG 76 -22 | 613.3 TN |
| 0425-1-351 | INLETS, CURB, TYPE P-5, <10' | 1 EA |
| 0425-1-361 | INLETS, CURB, TYPE P-6, <10' | 1 EA |
| 0425-2-63 | MANHOLES, P-8, PARTIAL | 1 EA |
| 0425-2-73 | MANHOLES, J-7, PARTIAL | 1 EA |
| 0425-6 | VALVE BOXES, ADJUST | 2 EA |
| 0430-175-118 | PIPE CULVERT,OPTIONAL MATERIAL,ROUND, 18"S/CD | 30 LF |
| 0520-1-10 | CONCRETE CURB & GUTTER, TYPE F | 922 LF |
| 0522-1 | CONCRETE SIDEWALK AND DRIVEWAYS, 4" THICK | 737 SY |
| 0522-2 | CONCRETE SIDEWALK AND DRIVEWAYS, 6" THICK | 52 SY |
| 0523-3 | PATTERNED PAVEMENT | 356 SY |
| 0527-2 | DETECTABLE WARNINGS | 69 SF |
| 0570-1-2 | PERFORMANCE TURF, SOD | 419 SY |
| 0639-8-130 | ELECTRICAL POWER SERVICE- CONTRIBUTION IN AID OF CONSTRUCTION (CIAC), FPL (DO NOT BID) (45456415201) | Lump sum |
| 0706-1-3 | RAISED PAVEMENT MARKER, TYPE B | 23 EA |
| 0710-11-101 | PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, SOLID, 6" | 0.21 GM |
| 0710-11-131 | PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, SKIP, 10-30 OR 3-9 SKIP, 6" WIDE | 0.18 GM |
| 0710-11-141 | PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, 2-4 DOTTED GUIDELINE/ 6-10 DOTTED EXTENSION, 6" | 0.08 GM |
| 0710-11-201 | PAINTED PAVEMENT MARKINGS, STANDARD, YELLOW, SOLID, 6" | 0.2 GM |
| 0999-25 | INITIAL CONTINGENCY AMOUNT, DO NOT BID (45456415201) | Lump sum |
| 0611-1-1 | ITSFM SUBSURFACE DOCUMENTATION- PROJECT LENGTH | 0.2 MI |
| 0611-2-2 | ITSFM LOCATION DOCUMENTATION- ITS SITE | 1 EA |
| 0630-2-11 | CONDUIT, FURNISH & INSTALL, OPEN TRENCH | 76 LF |
| 0630-2-12 | CONDUIT, FURNISH & INSTALL, DIRECTIONAL BORE | 138 LF |
| 0632-7-1 | SIGNAL CABLE- NEW OR RECONSTRUCTED INTERSECTION, FURNISH & INSTALL | 1 PI |
| 0633-6 | FIBER OPTIC CABLE LOCATOR | 192 DA |
| 0633-8-11 | MULTI-CONDUCTOR COMMUNICATION CABLE, FURNISH & INSTALL, CAT 6 | 32 LF |
| 0635-2-14 | PULL & SPLICE BOX, F&I, 17" X 30" COVER SIZE | 13 EA |
| 0641-2-13 | PRESTRESSED CONCRETE POLE, F&I, TYPE P-III | 1 EA |
| 0641-2-70 | PRESTRESSED CONCRETE POLE, SHALLOW POLE REMOVAL- POLE 30' AND GREATER | 1 EA |
| 0646-1-11 | ALUMINUM SIGNALS POLE, PEDESTAL | 3 EA |
| 0646-1-60 | ALUMINUM SIGNALS POLE, REMOVE | 2 EA |
| 0649-21-27 | STEEL MAST ARM ASSEMBLY, FURNISH AND INSTALL, DOUBLE ARM 78'-78' | 1 EA |
| 0649-26-3 | STEEL MAST ARM ASSEMBLY, REMOVE, SHALLOW FOUNDATION- BOLT ON ATTACHMENT | 1 EA |
| 0650-1-14 | VEHICULAR TRAFFIC SIGNAL, FURNISH & INSTALL ALUMINUM, 3 SECTION, 1 WAY | 7 AS |
| 0650-1-19 | VEHICULAR TRAFFIC SIGNAL, FURNISH & INSTALL ALUMINUM, 5 SECTION CLUSTER, 1 WAY | 1 AS |
| 0650-2-109 | VEHICULAR SIGNAL AUXILIARIES, REPAIR/REPLACE/RETROFIT- FURNISH & INSTALL, BACKPLATE- FLEXIBLE REQUIRED | 3 EA |
| 0653-1-11 | PEDESTRIAN SIGNAL, FURNISH & INSTALL LED COUNTDOWN, 1 WAY | 3 AS |
| 0660-1-101 | LOOP DETECTOR INDUCTIVE, F&I, TYPE 1 | 3 EA |
| 0660-2-106 | LOOP ASSEMBLY, F&I, TYPE F | 5 AS |
| 0660-4-11 | VEHICLE DETECTION SYSTEM- VIDEO, FURNISH & INSTALL CABINET EQUIPMENT | 1 EA |
| 0660-4-12 | VEHICLE DETECTION SYSTEM- VIDEO, FURNISH & INSTALL ABOVE GROUND EQUIPMENT | 1 EA |
| 0660-6-422 | VEHICLE DETECTION SYSTEM- AVI, BLUETOOTH RELOCATE, ABOVE GROUND EQUIPMENT | 1 EA |
| 0665-1-11 | PEDESTRIAN DETECTOR, FURNISH & INSTALL, STANDARD | 3 EA |
| 0671-2-40 | TRAFFIC CONTROLLER, MODIFY | 1 EA |
| 0682-1-400 | ITS CCTV CAMERA, RELOCATE | 1 EA |
| 0700-3-201 | SIGN PANEL, FURNISH & INSTALL OVERHEAD MOUNT, UP TO 12 SF | 2 EA |
| 0700-5-22 | INTERNALLY ILLUMINATED SIGN, FURNISH & INSTALL, OVERHEAD MOUNT, 12-18 SF | 1 EA |
| 0700-1-500 | SINGLE COLUMN GROUND SIGN ASSEMBLY, RELOCATE | 3 EA |
| 0700-1-600 | SINGLE COLUMN GROUND SIGN ASSEMBLY, REMOVE | 2 EA |
| 0700-2-600 | MULTI-COLUMN GROUND SIGN ASSEMBLY, REMOVE | 1 EA |
| 0700-13-15 | RETROREFLECTIVE SIGN STRIP- FURNISH AND INSTALL, 5' | 2 EA |
| 0706-1-3 | RAISED PAVEMENT MARKER, TYPE B | 98 EA |
| 0710-90 | PAINTED PAVEMENT MARKINGS, FINAL SURFACE (45456415201) | Lump sum |
| 0711-11-123 | THERMOPLASTIC, STANDARD, WHITE, SOLID, 12" FOR CROSSWALK AND ROUNDABOUT | 647 LF |
| 0711-11-125 | THERMOPLASTIC, STANDARD, WHITE, SOLID, 24" FOR STOP LINE AND CROSSWALK | 62 LF |
| 0711-11-141 | THERMOPLASTIC, STANDARD, WHITE, 2-4 DOTTED GUIDELINE/ 6-10 GAP EXTENSION, 6" | 0.13 GM |
| 0711-11-170 | THERMOPLASTIC, STANDARD, WHITE, ARROW | 3 EA |
| 0711-14-125 | THERMOPLASTIC, PREFORMED, WHITE, SOLID, 24" FOR CROSSWALK | 512 LF |
| 0711-14-160 | THERMOPLASTIC, PREFORMED, WHITE, MESSAGE | 4 EA |
| 0711-14-170 | THERMOPLASTIC, PREFORMED, WHITE, ARROW | 4 EA |
| 0711-16-101 | THERMOPLASTIC, STANDARD-OTHER SURFACES, WHITE, SOLID, 6" | 0.4 GM |
| 0711-16-131 | THERMOPLASTIC, STANDARD-OTHER SURFACES, WHITE, SKIP, 6",10-30 SKIP OR 3-9 LANE DROP | 0.53 GM |
| 0711-16-201 | THERMOPLASTIC, STANDARD-OTHER SURFACES, YELLOW, SOLID, 6" | 0.24 GM |
| 0630-2-12 | CONDUIT, FURNISH & INSTALL, DIRECTIONAL BORE | 1,153 LF |
| 0635-2-11 | PULL & SPLICE BOX, F&I, 13" x 24" COVER SIZE | 12 EA |
| 0639-1-122 | ELECTRICAL POWER SERVICE, F&I, UNDERGROUND, METER PURCHASED BY CONTRACTOR | 1 AS |
| 0639-2-1 | ELECTRICAL SERVICE WIRE, FURNISH & INSTALL | 160 LF |
| 0639-3-11 | ELECTRICAL SERVICE DISCONNECT, F&I, POLE MOUNT | 1 EA |
| 0641-2-12 | PRESTRESSED CONCRETE POLE, F&I, TYPE P-II SERVICE POLE | 1 EA |
| 0715-1-12 | LIGHTING CONDUCTORS, F&I, INSULATED, NO.8 - 6 | 3,459 LF |
| 0715-7-11 | LOAD CENTER, F&I, SECONDARY VOLTAGE | 1 EA |
| 0715-62-342 | LIGHT POLE COMPLETE, F&I, STANDARD POLE SPECIAL FOUNDATION, 40' MOUNTING HEIGHT, 12' ARM LENGTH | 2 EA |
| 0715-66-166 | LIGHT POLE COMPLETE, F&I, UTILITY CONFLICT POLE SPECIAL FOUNDATION, 30' MOUNTING HEIGHT, 16' ARM LENGTH | 2 EA |
| 0715-500-1 | POLE CABLE DISTRIBUTION SYSTEM, FURNISH AND INSTALL, CONVENTIONAL | 6 EA |
| 0715-540-000 | LIGHT POLE COMPLETE- SPECIAL DESIGN, RELOCATE | 2 EA |
| 0630-2-11 | CONDUIT, FURNISH & INSTALL, OPEN TRENCH | 880 LF |
| 0633-1-122 | FIBER OPTIC CABLE, F&I, UNDERGROUND,13-48 FIBERS | 2,559 LF |
| 0633-1-123 | FIBER OPTIC CABLE, F&I, UNDERGROUND,49-96 FIBERS | 2,559 LF |
| 0633-2-31 | FIBER OPTIC CONNECTION, INSTALL, SPLICE | 288 EA |
| 0635-2-15 | PULL & SPLICE BOX, F&I, 30" X 48" COVER SIZE | 2 EA |