Intersection
Fulton County · plans pulled by 5 GCs
Plan pull5 GCsJun 2
Pattern2 prime · 3 sub—
Bid dateThursday, June 11—
Fulton County · plans pulled by 5 GCs
Bid form · ODOT
As advertised by ODOT — 121 pay items with quantities and units. Contractor unit prices appear here once bids open.
| # | Item | Description | Quantity |
|---|---|---|---|
| 1 | 201E11000 | CLEARING AND GRUBBING | Lump sum |
| 2 | 202E23000 | PAVEMENT REMOVED | 8,724 SY |
| 3 | 202E34900 | PIPE REMOVED | 1,120 FT |
| 4 | 202E58000 | MANHOLE REMOVED | 2 EACH |
| 5 | 202E58100 | CATCH BASIN REMOVED | 4 EACH |
| 6 | 202E98100 | REMOVAL MISC.:CONCRETE SIGN FOUNDATION | 4 EACH |
| 7 | 203E10000 | EXCAVATION | 10,718 CY |
| 8 | 203E20000 | EMBANKMENT | 1,852 CY |
| 9 | 204E10000 | SUBGRADE COMPACTION | 9,911 SY |
| 10 | 204E13000 | EXCAVATION OF SUBGRADE, 14" | 93 CY |
| 11 | 204E30030 | GRANULAR MATERIAL, TYPE D,14" | 93 CY |
| 12 | 204E45000 | PROOF ROLLING | 6 HOUR |
| 13 | 204E50000 | GEOTEXTILE FABRIC | 76 SY |
| 14 | 206E10500 | CEMENT | 290 TON |
| 15 | 206E11000 | CURING COAT | 9,409 SY |
| 16 | 206E15020 | CEMENT STABILIZED SUBGRADE, 14 INCHES DEEP | 9,409 SY |
| 17 | 623E12000 | PRIMARY PROJECT CONTROL MONUMENT, TYPE A | 1 EACH |
| 18 | 601E21050 | TIED CONCRETE BLOCK MAT WITH TYPE 1 UNDERLAYMENT | 20 SY |
| 19 | 654E11000 | COMMERCIAL FERTILIZER | 1.9 TON |
| 20 | 659E00100 | SOIL ANALYSIS TEST | 2 EACH |
| 21 | 659E00300 | TOPSOIL | 1,559 CY |
| 22 | 659E10000 | SEEDING AND MULCHING | 14,041 SY |
| 23 | 659E14000 | REPAIR SEEDING AND MULCHING | 702 SY |
| 24 | 659E15000 | INTER-SEEDING | 702 SY |
| 25 | 659E31000 | LIME | 2.9 ACRE |
| # | Item | Description | Quantity |
|---|---|---|---|
| 26 | 659E35000 | WATER | 76 MGAL |
| 27 | 670E00500 | SLOPE EROSION PROTECTION | 3,411 SY |
| 28 | 832E15000 | STORM WATER POLLUTION PREVENTION PLAN | Lump sum |
| 29 | 832E15002 | STORM WATER POLLUTION PREVENTION INSPECTIONS | Lump sum |
| 30 | 832E15010 | STORM WATER POLLUTION PREVENTION INSPECTION SOFTWARE | Lump sum |
| 31 | 832E30000 | EROSION CONTROL | 60,000 EACH |
| 32 | 601E32200 | ROCK CHANNEL PROTECTION, TYPE C WITH FILTER | 20 CY |
| 33 | 602E20000 | CONCRETE MASONRY | 4.3 CY |
| 34 | 605E13300 | 6" UNCLASSIFIED PIPE UNDERDRAINS | 454 FT |
| 35 | 605E14000 | 6" BASE PIPE UNDERDRAINS | 3,093 FT |
| 36 | 611E00510 | 6" CONDUIT, TYPE F FOR UNDERDRAIN OUTLETS |
How to read this. Plan‑pull counts come straight from agency portals. Patterns and confidence scores are derived from comparable lettings (same county, same category, three‑year basis). Confidence is a calibration of past correctness on signals of this shape — not a guarantee of this bid’s outcome. We never round up. More on what Cassandri does →
| 205 FT |
| 37 | 611E01400 | 6" CONDUIT, TYPE E | 200 FT |
| 38 | 611E01500 | 6" CONDUIT, TYPE F | 300 FT |
| 39 | 611E04600 | 12" CONDUIT, TYPE C | 174 FT |
| 40 | 611E12400 | 27" CONDUIT, TYPE D | 48 FT |
| 41 | 611E52402 | 22" X 34" CONDUIT, TYPE B, 706.04 | 109 FT |
| 42 | 611E52404 | 22" X 34" CONDUIT, TYPE C, 706.04 | 24 FT |
| 43 | 611E52502 | 24" X 38" CONDUIT, TYPE B, 706.04 | 79 FT |
| 44 | 611E52504 | 24" X 38" CONDUIT, TYPE C, 706.04 | 73 FT |
| 45 | 611E98151 | CATCH BASIN, NO. 3, AS PER PLAN | 5 EACH |
| 46 | 611E98181 | CATCH BASIN, NO. 3A, AS PER PLAN | 5 EACH |
| 47 | 690E98300 | SPECIAL - SPECIAL, RIVER ROCK WITH WEED BARRIER | 265 SY |
| 48 | 252E01500 | FULL DEPTH PAVEMENT SAWING | 384 FT |
| 49 | 254E01000 | PAVEMENT PLANING, ASPHALT CONCRETE, 1.5" | 4,815 SY |
| 50 | 301E56000 | ASPHALT CONCRETE BASE, PG64-22, (449) | 115 CY |
| 51 | 304E20000 | AGGREGATE BASE | 2,063 CY |
| 52 | 407E10000 | TACK COAT | 644 GAL |
| 53 | 411E10000 | STABILIZED CRUSHED AGGREGATE | 87 CY |
| 54 | 441E70000 | ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (449), PG64-22 | 100 CY |
| 55 | 442E22101 | ASPHALT CONCRETE SURFACE COURSE, 12.5 MM, TYPE A (449), AS PER PLAN | 210 CY |
| 56 | 452E16010 | 13" NON-REINFORCED CONCRETE PAVEMENT, CLASS QC 1P | 7,395 SY |
| 57 | 452E19200 | NON-REINFORCED CONCRETE PAVEMENT, MISC.:9" CONCRETE STAMPED AND STAINED | 1,530 SY |
| 58 | 609E18001 | COMBINATION CURB AND GUTTER, TYPE 3, AS PER PLAN | 2,676 FT |
| 59 | 609E24510 | CURB, TYPE 4-C | 54 FT |
| 60 | 609E26000 | CURB, TYPE 6 | 104 FT |
| 61 | 609E31001 | COMBINATION CURB AND GUTTER, TYPE 9, AS PER PLAN | 295 FT |
| 62 | 609E33001 | CURB, TYPE 10, AS PER PLAN | 1,944 FT |
| 63 | 609E33200 | CURB, TYPE 10-B | 66 FT |
| 64 | 618E39000 | RUMBLE STRIPS, TRANSVERSE (ASPHALT CONCRETE) | 10 EACH |
| 65 | 625E00450 | CONNECTION, FUSED PULL APART | 24 EACH |
| 66 | 625E10490 | LIGHT POLE, CONVENTIONAL, AT8B30 | 12 EACH |
| 67 | 625E14000 | LIGHT POLE FOUNDATION, 24" X 6' DEEP | 12 EACH |
| 68 | 625E17960 | BRACKET ARM, 8' | 12 EACH |
| 69 | 625E23306 | NO. 10 AWG 600 VOLT DISTRIBUTION CABLE | 6,609 FT |
| 70 | 625E23400 | NO. 10 AWG POLE AND BRACKET CABLE | 1,548 FT |
| 71 | 625E25104 | CONDUIT, 1", 725.051 | 1,736 FT |
| 72 | 625E25900 | CONDUIT, JACKED OR DRILLED, 1", 725.04 | 277 FT |
| 73 | 625E26252 | LUMINAIRE, CONVENTIONAL, SOLID STATE (LED), 196W, TYPE III, 240V | 12 EACH |
| 74 | 625E29002 | TRENCH, 24" DEEP | 1,736 FT |
| 75 | 625E30500 | PULL BOX, 725.06, SIZE 1.5 | 6 EACH |
| 76 | 625E32000 | GROUND ROD | 13 EACH |
| 77 | 625E34000 | POWER SERVICE | 1 EACH |
| 78 | 625E36010 | UNDERGROUND WARNING MARKING TAPE | 1,736 FT |
| 79 | 620E60000 | DELINEATOR, POST SURFACE MOUNTED | 1 EACH |
| 80 | 620E60001 | DELINEATOR, POST SURFACE MOUNTED, AS PER PLAN | 3 EACH |
| 81 | 621E00100 | RPM, 2-WAY | 216 EACH |
| 82 | 630E03101 | GROUND MOUNTED SUPPORT, NO. 3 POST, AS PER PLAN | 680.25 FT |
| 83 | 630E08601 | SIGN POST REFLECTOR, AS PER PLAN | 16 EACH |
| 84 | 630E79500 | SIGN SUPPORT ASSEMBLY, POLE MOUNTED | 2 EACH |
| 85 | 630E80100 | SIGN, FLAT SHEET | 280.35 SF |
| 86 | 630E85000 | REMOVAL OF GROUND MOUNTED SIGN AND STORAGE | 34 EACH |
| 87 | 630E85100 | REMOVAL OF GROUND MOUNTED SIGN AND REERECTION | 13 EACH |
| 88 | 630E86006 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND STORAGE | 36 EACH |
| 89 | 630E86310 | REMOVAL OF STRUCTURE MOUNTED SIGN AND DISPOSAL | 52 EACH |
| 90 | 630E89814 | REMOVAL OF WOOD POLE AND STORAGE | 4 EACH |
| 91 | 631E94480 | REMOVAL OF PHOTOELECTRIC CONTROL | 4 EACH |
| 92 | 644E00104 | EDGE LINE, 6" | 0.46 MILE |
| 93 | 644E00300 | CENTER LINE, 4", DOUBLE YELLOW | 0.35 MILE |
| 94 | 644E00700 | TRANSVERSE/DIAGONAL LINE, YELLOW | 230 FT |
| 95 | 646E10010 | EDGE LINE, 6" | 1.12 MILE |
| 96 | 646E10200 | CENTER LINE, 4", DOUBLE YELLOW | 0.29 MILE |
| 97 | 646E10600 | TRANSVERSE/DIAGONAL LINE, YELLOW | 430 FT |
| 98 | 646E20300 | LANE ARROW, 8' | 4 EACH |
| 99 | 646E20510 | DOTTED LINE, 12", WHITE | 165 FT |
| 100 | 646E20800 | YIELD LINE, 24" X 36" TRIANGLES | 63 FT |
| 101 | 614E11110 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE | 120 HOUR |
| 102 | 614E11630 | INCREASED BARRIER DELINEATION | 940 FT |
| 103 | 614E12384 | WORK ZONE IMPACT ATTENUATOR, 24" WIDE HAZARDS, (BIDIRECTIONAL) | 2 EACH |
| 104 | 614E12420 | DETOUR SIGNING | Lump sum |
| 105 | 614E12757 | WORK ZONE CROSSOVER LIGHTING SYSTEM, AS PER PLAN | 2 EACH |
| 106 | 614E12801 | WORK ZONE RAISED PAVEMENT MARKER, AS PER PLAN | 325 EACH |
| 107 | 614E13310 | BARRIER REFLECTOR, TYPE 1, BIDIRECTIONAL | 20 EACH |
| 108 | 614E13360 | OBJECT MARKER, TWO WAY | 20 EACH |
| 109 | 614E18601 | PORTABLE CHANGEABLE MESSAGE SIGN, AS PER PLAN | 20 SNMT |
| 110 | 614E21000 | WORK ZONE CENTER LINE, CLASS I | 0.35 MILE |
| 111 | 614E22010 | WORK ZONE EDGE LINE, CLASS I, 6" | 0.59 MILE |
| 112 | 614E25000 | WORK ZONE TRANSVERSE/DIAGONAL LINE, CLASS I | 128 FT |
| 113 | 615E10000 | ROADS FOR MAINTAINING TRAFFIC | Lump sum |
| 114 | 615E20000 | PAVEMENT FOR MAINTAINING TRAFFIC, CLASS A | 3,902 SY |
| 115 | 616E10000 | WATER | 10 MGAL |
| 116 | 622E41100 | PORTABLE BARRIER, UNANCHORED | 940 FT |
| 117 | 103E05000 | PREMIUM FOR CONTRACT PERFORMANCE BOND AND FOR PAYMENT BOND | Lump sum |
| 118 | 108E10000 | CPM PROGRESS SCHEDULE | Lump sum |
| 119 | 614E11000 | MAINTAINING TRAFFIC | Lump sum |
| 120 | 623E10000 | CONSTRUCTION LAYOUT STAKES AND SURVEYING | Lump sum |
| 121 | 624E10000 | MOBILIZATION | Lump sum |
Cost concentration table renders only when the active letting’s own line items are present. The donut above is aggregated from this bid.