Off-Syst Mangana Hein Rd Becerra Creek
Webb County · est $2.5M
Webb County · est $2.5M
Plan requests are source-published interest, not bid submissions. Historical participants are the most frequent firms in the stored Texas work-type history over the past five years. Low bids describe published positions, not verified awards or predictions.
TxDOT source checked
No addenda matched in the stored source. Check TxDOT for current revisions before bidding.
Stored revisions can change. Confirm the current proposal and all applicable addenda with TxDOT.
How to read this. Bid amounts and plan requests are published TxDOT facts. Low bid describes a published position; it does not establish an agency award. Contractor links require an exact, unique match to the official vendor directory. Confirm current proposal revisions with TxDOT before bidding. More on what Cassandri does →
Bid form · TxDOT
121 advertised pay items from the TxDOT bid form. Open a category to see its items — unit prices appear here once bids open.
| 506-7002 | ROCK FILTER DAMS (INSTALL) (TY 2) | 30 LF |
| 506-7011 | ROCK FILTER DAMS (REMOVE) | 30 LF |
| 506-7039 | TEMP SEDMT CONT FENCE (INSTALL) | 360 LF |
| 506-7041 | TEMP SEDMT CONT FENCE (REMOVE) | 360 LF |
| 506-7002 | ROCK FILTER DAMS (INSTALL) (TY 2) | 150 LF |
| 506-7011 | ROCK FILTER DAMS (REMOVE) | 150 LF |
| 506-7039 | TEMP SEDMT CONT FENCE (INSTALL) | 600 LF |
| 506-7041 | TEMP SEDMT CONT FENCE (REMOVE) | 600 LF |
| 506-7002 | ROCK FILTER DAMS (INSTALL) (TY 2) | 30 LF |
| 506-7011 | ROCK FILTER DAMS (REMOVE) | 30 LF |
| 506-7039 | TEMP SEDMT CONT FENCE (INSTALL) | 390 LF |
| 506-7041 | TEMP SEDMT CONT FENCE (REMOVE) | 390 LF |
| 658-7004 | INSTL DEL ASSM (D-SW)SZ 1(WFLX)GND(BI) | 6 EA |
| 658-7013 | INSTL DEL ASSM (D-SW)SZ 1(BRF)CTB (BI) | 2 EA |
| 658-7056 | INSTL OM ASSM (OM-2Y)(WC)GND | 4 EA |
| 658-7004 | INSTL DEL ASSM (D-SW)SZ 1(WFLX)GND(BI) | 6 EA |
| 658-7013 | INSTL DEL ASSM (D-SW)SZ 1(BRF)CTB (BI) | 4 EA |
| 658-7056 | INSTL OM ASSM (OM-2Y)(WC)GND | 4 EA |
| 658-7003 | INSTL DEL ASSM (D-SW)SZ 1(WFLX)GND | 12 EA |
| 658-7032 | INSTL DEL ASSM (D-SY)SZ 1(BRF)CTB (BI) | 6 EA |
| 658-7268 | INSTL OM ASSM (OM-3L)(WFLX)GNDLL | 2 EA |
| 658-7276 | INSTL OM ASSM (OM-3R)(WFLX)GNDLL | 2 EA |
| 420-7012 | CL C CONC (ABUT) | 38.8 CY |
| 420-7022 | CL C CONC (CAP) | 12.8 CY |
| 420-7038 | CL C CONC (COLUMN) | 5.6 CY |
| 420-7012 | CL C CONC (ABUT) | 44.6 CY |
| 420-7022 | CL C CONC (CAP) | 30.4 CY |
| 420-7038 | CL C CONC (COLUMN) | 10.2 CY |
| 420-7069 | CL E CONC (SEAL SLAB) | 79 CY |
| 420-7150 | CL A CONC (CHANNEL LINING) | 12 CY |
| 420-7152 | CL C CONC (CULV) | 148 CY |
| 540-7001 | MTL W-BEAM GD FEN (TIM POST) | 300 LF |
| 540-7006 | MTL BEAM GD FEN TRANS (TL2) | 4 EA |
| 540-7015 | DOWNSTREAM ANCHOR TERMINAL SECTION | 2 EA |
| 540-7001 | MTL W-BEAM GD FEN (TIM POST) | 300 LF |
| 540-7006 | MTL BEAM GD FEN TRANS (TL2) | 4 EA |
| 540-7015 | DOWNSTREAM ANCHOR TERMINAL SECTION | 2 EA |
| 110-7001 | EXCAV (ROADWAY) | 154 CY |
| 110-7002 | EXCAV (CHANNEL) | 700 CY |
| 110-7001 | EXCAV (ROADWAY) | 72 CY |
| 110-7002 | EXCAV (CHANNEL) | 840 CY |
| 110-7001 | EXCAV (ROADWAY) | 124 CY |
| 432-7013 | RIPRAP (MOW STRIP)(4 IN) | 22 CY |
| 432-7041 | RIPRAP (STONE PROTECTION)(12 IN) | 494 CY |
| 432-7013 | RIPRAP (MOW STRIP)(4 IN) | 22 CY |
| 432-7041 | RIPRAP (STONE PROTECTION)(12 IN) | 558 CY |
| 432-7001 | RIPRAP (CONC)(4 IN) | 12 CY |
| 341-7002 | D-GR HMA TY-B SAC-B PG64-22 | 169 TON |
| 341-7031 | D-GR HMA TY-C SAC-A PG76-22 | 99 TON |
| 341-7002 | D-GR HMA TY-B SAC-B PG64-22 | 105 TON |
| 341-7031 | D-GR HMA TY-C SAC-A PG76-22 | 70 TON |
| 422-7001 | REINF CONC SLAB | 2,400 SF |
| 422-7013 | APPROACH SLAB | 45 CY |
| 422-7001 | REINF CONC SLAB | 5,700 SF |
| 422-7013 | APPROACH SLAB | 63 CY |
| 496-7009 | REMOV STR (BRIDGE 0 - 99 FT LENGTH) | 1 EA |
| 496-7010 | REMOV STR (BRIDGE 100 - 499 FT LENGTH) | 1 EA |
| 496-7005 | REMOV STR (WINGWALL) | 4 EA |
| 496-7008 | REMOV STR (BOX CULVERT) | 86 LF |
| 644-7001 | IN SM RD SN SUP&AM TY10BWG(1)SA(P) | 2 EA |
| 644-7073 | REMOVE SM RD SN SUP&AM | 2 EA |
| 644-7073 | REMOVE SM RD SN SUP&AM | 4 EA |
| 644-7073 | REMOVE SM RD SN SUP&AM | 1 EA |
| 666-7293 | TY I HIGH PERF PM (W)6"(SLD)(100MIL) | 760 LF |
| 666-7305 | TY I HIGH PERF PM (Y)6"(SLD)(100MIL) | 960 LF |
| 666-7533 | RE PM TY II (W)6"(SLD)(020 MIL) | 1,609 LF |
| 666-7537 | RE PM TY II (Y)6"(SLD)(020 MIL) | 466 LF |
| 100-7002 | PREPARING ROW | 4 STA |
| 100-7002 | PREPARING ROW | 5 STA |
| 100-7002 | PREPARING ROW | 2 STA |
| 105-7014 | RMV (14"-18") TRT/UNTRT BASE & ASPH PAV | 966 SY |
| 105-7014 | RMV (14"-18") TRT/UNTRT BASE & ASPH PAV | 988 SY |
| 105-7058 | RMV (7"-13") TRT/UNTRT BASE & ASPH PAV | 572 SY |
| 132-7006 | EMBANK (FNL)(DC)(TY C) | 372 CY |
| 132-7006 | EMBANK (FNL)(DC)(TY C) | 297 CY |
| 132-7006 | EMBANK (FNL)(DC)(TY C) | 50 CY |
| 216-7001 | PROOF ROLLING | 8 HR |
| 216-7001 | PROOF ROLLING | 8 HR |
| 216-7001 | PROOF ROLLING | 8 HR |
| 247-7067 | FL BS (CMP IN PLC)(TY A GR 1-2) (8") | 1,070 SY |
| 247-7044 | FL BS (CMP IN PLC)(TY A GR 1-2) (6") | 1,051 SY |
| 247-7067 | FL BS (CMP IN PLC)(TY A GR 1-2) (8") | 654 SY |
| 310-7004 | PRIME COAT (MC-30) | 214 GAL |
| 310-7004 | PRIME COAT (MC-30) | 184 GAL |
| 310-7004 | PRIME COAT (MC-30) | 131 GAL |
| 400-7010 | CEM STABIL BKFL | 95 CY |
| 400-7010 | CEM STABIL BKFL | 105 CY |
| 400-7010 | CEM STABIL BKFL | 82 CY |
| 403-7001 | TEMPORARY SPL SHORING | 890 SF |
| 403-7001 | TEMPORARY SPL SHORING | 1,031 SF |
| 403-7001 | TEMPORARY SPL SHORING | 854 SF |
| 416-7006 | DRILL SHAFT (36 IN) | 231 LF |
| 416-7002 | DRILL SHAFT (18 IN) | 136 LF |
| 416-7006 | DRILL SHAFT (36 IN) | 306 LF |
| 450-7008 | RAIL (TY T223) | 208 LF |
| 450-7008 | RAIL (TY T223) | 436 LF |
| 450-7008 | RAIL (TY T223) | 58 LF |
| 425-7001 | PRESTR CONC GIRDER (TX28) | 395.01 LF |
| 425-7001 | PRESTR CONC GIRDER (TX28) | 942.25 LF |
| 454-7004 | SEALED EXPANSION JOINT (4 IN) (SEJ - M) | 60 LF |
| 454-7004 | SEALED EXPANSION JOINT (4 IN) (SEJ - M) | 69 LF |
| 544-7001 | GUARDRAIL END TREATMENT (INSTALL) | 2 EA |
| 544-7001 | GUARDRAIL END TREATMENT (INSTALL) | 2 EA |
| 681-7001 | TEMP TRAF SIGNALS | 2 EA |
| 681-7001 | TEMP TRAF SIGNALS | 2 EA |
| 3007-7001 | BONDING COURSE | 188 GAL |
| 3007-7001 | BONDING COURSE | 127 GAL |
| 104-7006 | REMOV CONC (RIPRAP) | 134 SY |
| 104-7017 | REMOV CONC (CURB & GUTTER) | 349 LF |
| 529-7008 | CONC CURB & GUTTER (TY I) | 31 LF |
| 529-7009 | CONC CURB & GUTTER (TY II) | 294 LF |
| 500-7001 | MOBILIZATION | Lump sum |
| 502-7001 | BARRICADES, SIGNS AND TRAFFIC HANDLING | 13 MO |
| 542-7001 | REMOVE METAL BEAM GUARD FENCE | 728 LF |
| 662-7017 | WK ZN PAV MRK NON-REMOV (W)24"(SLD) | 56 LF |
| 672-7002 | REFL PAV MRKR TY I-C | 28 EA |
| 678-7002 | PAV SURF PREP FOR MRK (6") | 20 LF |
| 330-7005 | LRA PAV TY-I GR-CC | 97 TON |
| 401-7001 | FLOWABLE BACKFILL | 185 CY |
| 466-7149 | WINGWALL (FW - 0) (HW=7 FT) | 4 EA |
| 530-7010 | DRIVEWAYS (ACP) | 92 SY |