Guardrail Rebuilding
plans pulled by 1 GCs
plans pulled by 1 GCs
1 sub pulled plans · Lake Erie Construction Company wins 52% of OH safety bids it enters
If your number lands…historical win odds, OH
Share of OH bids over the last 5 years that landed there vs the official estimate and won (n=9,472 bids) — historical frequency, not a forecast. ODOT's estimate stays sealed until bids open.
Pulled plans1 sub
Likely also biddingOH safety regulars · 7
Confirmed = pulled plans on this letting (revealed interest, from the agency portal). Likely = firms that bid OH safety work in the last 5 years, ranked by frequency. Win rate is historical — the share of bids that firm entered and won, not a prediction of this letting.
How to read this. Plan‑pull counts come straight from agency portals. Patterns and confidence scores are derived from comparable lettings (same county, same category, three‑year basis). Confidence is a calibration of past correctness on signals of this shape — not a guarantee of this bid’s outcome. We never round up. More on what Cassandri does →
Bid form · ODOT
114 advertised pay items from the ODOT bid form. Open a category to see its items — unit prices appear here once bids open.
| 202E38000 | GUARDRAIL REMOVED | 10,000 FT |
| 202E38500 | BRIDGE RAILING REMOVED | 500 FT |
| 202E42000 | ANCHOR ASSEMBLY REMOVED, TYPE A | 10 EACH |
| 202E42010 | ANCHOR ASSEMBLY REMOVED, TYPE E | 40 EACH |
| 202E42040 | ANCHOR ASSEMBLY REMOVED, TYPE T | 10 EACH |
| 202E42050 | ANCHOR ASSEMBLY REMOVED, TYPE B | 5 EACH |
| 202E47000 | BRIDGE TERMINAL ASSEMBLY REMOVED | 5 EACH |
| 202E47800 | IMPACT ATTENUATOR REMOVED | 6 EACH |
| 203E20000 | EMBANKMENT | 10 CY |
| 517E75501 | BRIDGE RAILING REBUILT, AS PER PLAN | 1,000 FT |
| 606E13000 | GUARDRAIL, TYPE 5 | 8,000 FT |
| 606E13030 | GUARDRAIL, TYPE 5, USING 9 FOOT POSTS | 100 FT |
| 606E13050 | GUARDRAIL, TYPE 5A | 100 FT |
| 606E15050 | GUARDRAIL, TYPE MGS | 1,000 FT |
| 606E15100 | GUARDRAIL, TYPE MGS WITH LONG POSTS | 200 FT |
| 606E15500 | GUARDRAIL, BARRIER DESIGN, TYPE 5 | 200 FT |
| 606E16001 | GUARDRAIL REBUILT, AS PER PLAN | 5,000 FT |
| 606E16051 | GUARDRAIL REBUILT, TYPE MGS, AS PER PLAN | 750 FT |
| 606E17290 | GUARDRAIL, TYPE 5, LONG-SPAN | 25 FT |
| 606E17360 | GUARDRAIL, TYPE MGS, LONG-SPAN | 25 FT |
| 606E17700 | REPLACE EXISTING GUARDRAIL BLOCKOUT | 200 EACH |
| 606E17750 | REPLACE EXISTING GUARDRAIL BLOCKOUT, TYPE MGS | 100 EACH |
| 606E17901 | GUARDRAIL POST, AS PER PLAN | 300 EACH |
| 606E18500 | GUARDRAIL POST, 9 FEET | 50 EACH |
| 606E18501 | GUARDRAIL POST, 9 FEET, AS PER PLAN | 30 EACH |
| 606E25000 | ANCHOR ASSEMBLY, TYPE A | 10 EACH |
| 606E25550 | ANCHOR ASSEMBLY, MGS TYPE A | 1 EACH |
| 606E26000 | ANCHOR ASSEMBLY, TYPE B | 5 EACH |
| 606E26050 | ANCHOR ASSEMBLY, MGS TYPE B | 1 EACH |
| 606E26150 | ANCHOR ASSEMBLY, MGS TYPE E (MASH 2016) | 60 EACH |
| 606E26500 | ANCHOR ASSEMBLY, TYPE T | 15 EACH |
| 606E26550 | ANCHOR ASSEMBLY, MGS TYPE T | 5 EACH |
| 606E27801 | ANCHOR ASSEMBLY REBUILT, TYPE A, AS PER PLAN | 12 EACH |
| 606E27841 | ANCHOR ASSEMBLY REBUILT, TYPE B, AS PER PLAN (12.5 FT. GUARDRAIL, | 10 EACH |
| 606E27841 | ANCHOR ASSEMBLY REBUILT, TYPE B, AS PER PLAN (BUFFER/ROLLED TERMINAL) | 5 EACH |
| 606E27841 | ANCHOR ASSEMBLY REBUILT, TYPE B, AS PER PLAN (CABLE ASSEMBLY) | 2 EACH |
| 606E27841 | ANCHOR ASSEMBLY REBUILT, TYPE B, AS PER PLAN (WOOD BLOCKS) | 5 EACH |
| 606E27841 | ANCHOR ASSEMBLY REBUILT, TYPE B, AS PER PLAN (WOOD POST, 45 IN. OR WOOD POST 72 IN.) | 10 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (CABLE ANCHOR BRACKET) | 6 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (CABLE ASSEMBLY) | 5 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (DEEP BEAM GUARDRAIL 12 GUAGE - 12.5 FT. OR DEEP BEAM GUARDRAIL-12.5 FT. END PANEL) | 15 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (DEEP BEAM GUARDRAIL 12 GUAGE - 25 FT. OR DEEP BEAM GUARDRAIL-25 FT. END PANEL) | 30 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (GUARDRAIL EXTRUDER) | 5 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (HBA POST #1-#4 BOTTOM) | 8 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (HBA POST #1-#4 TOP) | 15 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (POST SYT #2-#8) | 6 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (STEEL FOUNDATION TUBE) | 2 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (STRUT) | 6 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (WOOD BLOCKS) | 20 EACH |
| 606E27851 | ANCHOR ASSEMBLY REBUILT, TYPE E, AS PER PLAN (WOOD POST, 45 IN. OR | 30 EACH |
| 606E27900 | ANCHOR ASSEMBLY REBUILT, TYPE T | 10 EACH |
| 606E27910 | ANCHOR ASSEMBLY REBUILT, MGS TYPE T | 2 EACH |
| 606E32160 | BRIDGE TERMINAL ASSEMBLY, TYPE TST | 2 EACH |
| 606E32171 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE TST, AS PER PLAN (12.5 FT. SINGLE W-BEAM RAIL ELEMENT) | 2 EACH |
| 606E32171 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE TST, AS PER PLAN (THRIE- BEAM ELEMENT, TRANSITION SECTION OR TERMINAL CONNECTOR) | 2 EACH |
| 606E32171 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE TST, AS PER PLAN (WOOD OR STEEL POST) | 2 EACH |
| 606E35000 | BRIDGE TERMINAL ASSEMBLY, TYPE 1 | 5 EACH |
| 606E35002 | MGS BRIDGE TERMINAL ASSEMBLY, TYPE 1 | 2 EACH |
| 606E35011 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (12.5 FT. RAIL ELEMENT) | 2 EACH |
| 606E35011 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (THRIE BEAM RAIL ELEMENT, TRANSITION SECTION OR TERMINAL CONNECTOR) | 5 EACH |
| 606E35011 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (WOOD POST OR STEEL POST) | 5 EACH |
| 606E35013 | MGS BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (12.5 FT. RAIL ELEMENT) | 2 EACH |
| 606E35013 | MGS BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (THRIE BEAM RAIL ELEMENT, TRANSITION SECTION OR TERMINAL CONNECTOR) | 2 EACH |
| 606E35013 | MGS BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 1, AS PER PLAN (WOOD POST OR STEEL POST) | 2 EACH |
| 606E35100 | BRIDGE TERMINAL ASSEMBLY, TYPE 2 | 2 EACH |
| 606E35102 | MGS BRIDGE TERMINAL ASSEMBLY, TYPE 2 | 2 EACH |
| 606E35140 | BRIDGE TERMINAL ASSEMBLY, TYPE 4 | 2 EACH |
| 606E35151 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 4, AS PER PLAN (12.5 FT. RAIL ELEMENT) | 6 EACH |
| 606E35151 | BRIDGE TERMINAL ASSEMBLY REBUILT, TYPE 4, AS PER PLAN (WOOD POST OR STEEL POST) | 15 EACH |
| 606E39001 | 36" CONCRETE ANCHOR REMOVED AND REPLACED, AS PER PLAN | 1 EACH |
| 606E50000 | SPECIAL - RESHAPING BERM | 150 FT |
| 606E54950 | SPECIAL - CABLE BARRIER (ANCHOR TRIGGER POST) | 2 EACH |
| 606E54950 | SPECIAL - CABLE BARRIER (LINE POST) | 500 EACH |
| 606E55020 | SPECIAL - CABLE BARRIER, REPLACEMENT CABLE | 100 FT |
| 606E55100 | SPECIAL - CABLE BARRIER, CONCRETE LINE POST FOUNDATION | 40 EACH |
| 606E55110 | SPECIAL - CABLE BARRIER, CONCRETE ANCHOR FOUNDATION WITH SLEEVE | 2 EACH |
| 606E55140 | SPECIAL - CABLE BARRIER, ANCHOR POST | 5 EACH |
| 606E55180 | SPECIAL - CABLE BARRIER, SPLICE | 5 EACH |
| 606E55190 | SPECIAL - CABLE BARRIER, POST REFLECTOR | 80 EACH |
| 606E55200 | SPECIAL - CABLE BARRIER, TENSIONING (ANNUAL) | 225 EACH |
| 606E55200 | SPECIAL - CABLE BARRIER, TENSIONING (REPAIR) | 25 EACH |
| 606E55220 | SPECIAL - CABLE BARRIER, ANCHOR POST RESET | 20 EACH |
| 606E60002 | IMPACT ATTENUATOR, TYPE 1 (UNIDIRECTIONAL) | 2 EACH |
| 606E60012 | IMPACT ATTENUATOR, TYPE 1 (BIDIRECTIONAL) | 2 EACH |
| 606E60022 | IMPACT ATTENUATOR, TYPE 2 (UNIDIRECTIONAL) (VARIOUS SPEED AND WIDTH) | 1 EACH |
| 606E60028 | IMPACT ATTENUATOR, TYPE 2 (BIDIRECTIONAL) (VARIOUS SPEED AND WIDTH) | 1 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (1/4" X 18" X 24" SOIL PLATE) | 2 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (3'-6" WOOD POST #1, 2, 3, 4, 5, 6 CAT) | 8 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (4'-6" FOUNDATION TUBE) | 1 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (ALL COMPONENTS POST # 4 TO POST #6, EXCLUDING POSTS, WOOD BLOCKS, FOUNDATION TUBES AND SOIL PLATES) | 2 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (ALL COMPONENTS POST #1 TO POST #4, EXCLUDING POSTS, WOOD BLOCKS, FOUNDATION TUBES AND SOIL PLATES) | 1 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (BELT NOSE ASSEMBLY) | 1 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (CARTRIDGE TYPE I) | 2 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (CARTRIDGE TYPE II) | 3 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (QUAD BEAM FENDER PANEL) | 3 EACH |
| 606E61000 | IMPACT ATTENUATOR, MISC.: (WOOD BLOCK 1'-2", POST #1, 2, 3, 4, 5, 6 CAT) | 10 EACH |
| 606E98000 | GUARDRAIL, MISC.: TUBULAR BACKUP | 50 FT |
| 606E98100 | GUARDRAIL, MISC.: (TYPE A ANCHOR) | 15 EACH |
| 606E98100 | GUARDRAIL, MISC.: (URGENT REPAIR) | 30 EACH |
| 606E98100 | GUARDRAIL, MISC.:ANCHOR ASSEMBLY REBUILT, TYPE A, BARRIER DESIGN | 1 EACH |
| 614E11110 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE | 50 HOUR |
| 614E13600 | MAINTENANCE OF TRAFFIC, ONE LANE CLOSURE ON A TWO LANE HIGHWAY | 200 EACH |
| 614E13700 | MAINTENANCE OF TRAFFIC, ONE LANE CLOSURE ON A FOUR LANE UNDIVIDED HIGHWAY | 6 EACH |
| 614E13800 | MAINTENANCE OF TRAFFIC, ONE LANE CLOSURE ON A 4 LANE OR GREATER DIVIDED HIGHWAY | 25 EACH |
| 614E13900 | MAINTENANCE OF TRAFFIC FOR SHOULDER CLOSURE | 250 EACH |
| 517E70000 | RAILING (TWIN STEEL TUBE) | 25 FT |
| 517E72300 | RAILING (DEEP BEAM RAIL WITH STEEL TUBULAR BACKUP AND TYPE 2 STEEL POSTS AND ANCHOR BOLTS) | 200 FT |
| 517E72750 | RAILING (THRIE BEAM RETROFIT) | 25 FT |
| 659E10001 | SEEDING AND MULCHING, AS PER PLAN | 100 SY |
| 832E30000 | EROSION CONTROL | 1,000 EACH |
| 626E00110 | BARRIER REFLECTOR, TYPE 2 (1 WAY) | 15 EACH |
| 626E00110 | BARRIER REFLECTOR, TYPE 2 (BIDIRECTIONAL) | 15 EACH |
| 103E05000 | PREMIUM FOR CONTRACT PERFORMANCE BOND AND FOR PAYMENT BOND | Lump sum |
| 624E10000 | MOBILIZATION | Lump sum |