Bonnewitz Avenue Signal
Van Wert County · plans pulled by 2 GCs
Van Wert County · plans pulled by 2 GCs
2 subs pulled plans · Shelly Company wins 47% of OH signals bids it enters
If your number lands…historical win odds, OH
Share of OH bids over the last 5 years that landed there vs the official estimate and won (n=9,593 bids) — historical frequency, not a forecast. ODOT's estimate stays sealed until bids open.
Pulled plans2 subs
Likely also biddingOH signals regulars · 8
Confirmed = pulled plans on this letting (revealed interest, from the agency portal). Likely = firms that bid OH signalswork in the last 3 years, ranked by where and how recently they bid it — firms most active in this project’s county and ODOT district rank first. Win rate is historical — the share of bids that firm entered and won, not a prediction of this letting.
How to read this. Plan‑pull counts come straight from agency portals. Patterns and confidence scores are derived from comparable lettings (same county, same category, three‑year basis). Confidence is a calibration of past correctness on signals of this shape — not a guarantee of this bid’s outcome. We never round up. More on what Cassandri does →
Bid form · ODOT
91 advertised pay items from the ODOT bid form. Open a category to see its items — unit prices appear here once bids open.
| 611E00400 | 4" CONDUIT, TYPE E | 80 FT |
| 625E18201 | BRACKET ARM, 15', AS PER PLAN | 3 EACH |
| 625E25408 | CONDUIT, 2", 725.051 | 168 FT |
| 625E25504 | CONDUIT, 3", 725.051 | 82 FT |
| 625E25604 | CONDUIT, 4", 725.051 | 168 FT |
| 625E25909 | CONDUIT, JACKED OR DRILLED, 725.052, AS PER PLAN, 3" | 299 FT |
| 625E25909 | CONDUIT, JACKED OR DRILLED, 725.052, AS PER PLAN, 4" | 86 FT |
| 625E26253 | LUMINAIRE, CONVENTIONAL, SOLID STATE (LED), AS PER PLAN, IES-III-M, | 3 EACH |
| 625E29000 | TRENCH | 334 FT |
| 625E30700 | PULL BOX, 725.08, 18" | 2 EACH |
| 625E30706 | PULL BOX, 725.08, 24" | 3 EACH |
| 625E32000 | GROUND ROD | 11 EACH |
| 625E36010 | UNDERGROUND WARNING MARKING TAPE | 334 FT |
| 625E76000 | ARC FLASH CALCULATIONS AND LABEL, SIGNAL POWER SERVICE | 1 EACH |
| 632E05007 | VEHICULAR SIGNAL HEAD, (LED), 3-SECTION, 12" LENS, 1-WAY, POLYCARBONATE, AS PER PLAN, BLACK | 6 EACH |
| 632E05087 | VEHICULAR SIGNAL HEAD, (LED), 5-SECTION, 12" LENS, 1-WAY, POLYCARBONATE, AS PER PLAN, BLACK | 2 EACH |
| 632E20731 | PEDESTRIAN SIGNAL HEAD (LED), TYPE D2, COUNTDOWN, AS PER PLAN | 8 EACH |
| 632E20751 | ACCESSIBLE PEDESTRIAN PUSHBUTTON, AS PER PLAN | 8 EACH |
| 632E25000 | COVERING OF VEHICULAR SIGNAL HEAD | 8 EACH |
| 632E25010 | COVERING OF PEDESTRIAN SIGNAL HEAD | 8 EACH |
| 632E40500 | SIGNAL CABLE, 5 CONDUCTOR, NO. 14 AWG | 2,825 FT |
| 632E40700 | SIGNAL CABLE, 7 CONDUCTOR, NO. 14 AWG | 1,237 FT |
| 632E62820 | INTERCONNECT, MISC.: SPREAD SPECTRUM RADIO UNIT | 2 EACH |
| 632E64011 | SIGNAL SUPPORT FOUNDATION, AS PER PLAN | 4 EACH |
| 632E64020 | PEDESTAL FOUNDATION | 6 EACH |
| 632E65300 | LOOP DETECTOR LEAD-IN CABLE, 2 CONDUCTOR, NO. 14 AWG | 1,928 FT |
| 632E68300 | POWER CABLE, 3 CONDUCTOR, NO. 6 AWG | 80 FT |
| 632E70001 | POWER SERVICE, AS PER PLAN | 1 EACH |
| 632E70400 | CONDUIT RISER, 2" DIAMETER | 1 EACH |
| 632E72141 | SIGNAL SUPPORT, TYPE TC-81.22, DESIGN 13, AS PER PLAN | 1 EACH |
| 632E79131 | COMBINATION SIGNAL SUPPORT, TYPE TC-81.22, DESIGN 12, AS PER PLAN | 2 EACH |
| 632E79151 | COMBINATION SIGNAL SUPPORT, TYPE TC-81.22, DESIGN 14, AS PER PLAN | 1 EACH |
| 632E89921 | PEDESTAL, 10.7' TALL, TRANSFORMER BASE, AS PER PLAN | 6 EACH |
| 632E90101 | REMOVAL OF TRAFFIC SIGNAL INSTALLATION, AS PER PLAN | 1 EACH |
| 633E65511 | CABINET, TYPE TS-2, AS PER PLAN | 1 EACH |
| 633E67100 | CABINET FOUNDATION | 1 EACH |
| 633E67201 | CONTROLLER WORK PAD, AS PER PLAN | 1 EACH |
| 633E75001 | UNINTERRUPTIBLE POWER SUPPLY (UPS), 1000 WATT, AS PER PLAN | 1 EACH |
| 633E99000 | CONTROLLER ITEM, MISC.:SIGNAL TIMING ADJUSTMENTS | 1 EACH |
| 809E69101 | STOP LINE RADAR DETECTION, AS PER PLAN | 4 EACH |
| 809E69123 | ATC CONTROLLER, AS PER PLAN | 1 EACH |
| 809E69201 | EMERGENCY VEHICLE PREEMPTION, AS PER PLAN | 1 EACH |
| 809E69211 | PREEMPT RECEIVING UNIT, AS PER PLAN | 4 EACH |
| 809E69221 | PREEMPT DETECTOR CABLE, AS PER PLAN | 1,220 FT |
| 809E69231 | PREEMPT PHASE SELECTOR, AS PER PLAN | 1 EACH |
| 809E69241 | PREEMPT CONFIRMATION LIGHT, AS PER PLAN | 4 EACH |
| 202E30000 | WALK REMOVED | 1,343 SF |
| 202E32500 | CURB AND GUTTER REMOVED | 234 FT |
| 202E75610 | VALVE BOX REMOVED | 1 EACH |
| 202E98000 | REMOVAL MISC.: REMOVED | Lump sum |
| 203E10000 | EXCAVATION | 102 CY |
| 204E10000 | SUBGRADE COMPACTION | 152 SY |
| 204E13000 | EXCAVATION OF SUBGRADE | 51 CY |
| 608E10000 | 4" CONCRETE WALK | 257 SF |
| 608E13000 | 6" CONCRETE WALK | 488 SF |
| 608E52000 | CURB RAMP (4" THICK) | 803 SF |
| 608E52000 | CURB RAMP (6" THICK) | 81 SF |
| 608E52000 | CURB RAMP (8" THICK) | 34 SF |
| 630E03100 | GROUND MOUNTED SUPPORT, NO. 3 POST | 13 FT |
| 630E79101 | SIGN HANGER ASSEMBLY, MAST ARM, AS PER PLAN | 6 EACH |
| 630E80100 | SIGN, FLAT SHEET | 34 SF |
| 630E80511 | SIGN, STREET NAME, AS PER PLAN | 4 EACH |
| 630E85000 | REMOVAL OF GROUND MOUNTED SIGN AND STORAGE | 2 EACH |
| 630E86006 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND STORAGE | 1 EACH |
| 644E00300 | CENTER LINE | 0.03 MILE |
| 644E00404 | CHANNELIZING LINE, 12" | 100 FT |
| 644E00500 | STOP LINE | 48 FT |
| 644E00620 | CROSSWALK LINE, 12" | 356 FT |
| 644E30000 | REMOVAL OF PAVEMENT MARKING | 516 FT |
| 301E56100 | ASPHALT CONCRETE BASE, PG64-22, (449), (DRIVEWAYS) | 2 CY |
| 304E20000 | AGGREGATE BASE | 29 CY |
| 407E20000 | NON-TRACKING TACK COAT (APPLIED @0.06 GAL/SY) | 8 GAL |
| 411E10000 | STABILIZED CRUSHED AGGREGATE | 17 CY |
| 441E70000 | ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (449), PG64-22 | 6 CY |
| 609E12001 | COMBINATION CURB AND GUTTER, TYPE 2, AS PER PLAN | 234 FT |
| 609E33201 | CURB, TYPE 10-B, AS PER PLAN | 62 FT |
| 609E57000 | 8" CONCRETE TRAFFIC ISLAND | 8 SY |
| 613E41200 | LOW STRENGTH MORTAR BACKFILL | 7 CY |
| 103E05000 | PREMIUM FOR CONTRACT PERFORMANCE BOND AND FOR PAYMENT BOND | Lump sum |
| 614E11000 | MAINTAINING TRAFFIC | Lump sum |
| 623E10001 | CONSTRUCTION LAYOUT STAKES AND SURVEYING, AS PER PLAN | Lump sum |
| 624E10000 | MOBILIZATION | Lump sum |
| 611E00100 | 4" CONDUIT, TYPE B, 707.45, STORM REPAIR | 50 FT |
| 611E00900 | 6" CONDUIT, TYPE B, 707.45, STORM REPAIR | 50 FT |
| 611E01800 | 8" CONDUIT, TYPE B, 707.45, STORM REPAIR | 50 FT |
| 659E00501 | SEEDING AND MULCHING, CLASS 1, AS PER PLAN | 66 SY |
| 832E30000 | EROSION CONTROL | 1,500 EACH |
| 614E11111 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE, AS PER PLAN | 16 HOUR |
| 616E10000 | WATER | 1 MGAL |
| 623E50000 | PRECONSTRUCTION SURVEY MONUMENT VERIFICATION AND REPORT NR) | Lump sum |
| 623E51000 | POST CONSTRUCTION SURVEY MONUMENT VERIFICATION AND REPORT | Lump sum |